Khởi động mềm 3 pha 7A 2HP SMC920020-SP Jaki-Taiwan
Khởi động mềm 3 pha 220V 7A 2HP SMC920020-SP Jaki-Taiwan
10,000₫
Nguồn điện chính: AC 208/220/380/440/480 VAC ± 10%
Điện áp phụ: AC 220 V ± 15% 50 / 60Hz
Start way: dry contact point
Dòng điện định mức: 4A ~ 28A
Công Suất: 2HP ~ 15HP
Tần suất làm việc: 50 ~ 60Hz ± 5%
1. Soft start time, start torque and soft stop time can be adjusted, let soft starter smooth.
2. 3 starting ways can be choice in this machine: slope starter, current-limit starter, current-limit and kick starter.
3. Use the S.C.R. control: No contacts, no arc, no wear and tear, the equivalent of semipermanent life.
4. Wiring easy: installation of 3 in 3 out, save the coast of hand wiring.
5. This controller is microprocessor with the function of automatic light/heavy loading revision and torque control.
6. Cooling fans has temperature control, the cooling sheet working at 55C, and stop at 45C, this design can extend use-life of fans 2-3 times.
7. The controller inside electronic sensor of CT: overload protection, input power loss the phase protection, motor block protection, controller over temperature protection, low load protection, exceed sensitive reaction, and no thermal effect, not affected by ambient temperature.
8. The machine has 3 sets output connection points: The output point when starting (Running), after running the output contacts (by Pass), and output point for system abnormal (NO, COM NC).
9. This machine has soft stop function for pump motor to create best water hammer removing result
1. Soft start time, start torque and soft stop time can be adjusted, let soft starter smooth.
2. 3 starting ways can be choice in this machine: slope starter, current-limit starter, current-limit and kick starter.
3. Use the S.C.R. control: No contacts, no arc, no wear and tear, the equivalent of semipermanent life.
4. Wiring easy: installation of 3 in 3 out, save the coast of hand wiring.
5. This controller is microprocessor with the function of automatic light/heavy loading revision and torque control.
6. Cooling fans has temperature control, the cooling sheet working at 55C, and stop at 45C, this design can extend use-life of fans 2-3 times.
7. The controller inside electronic sensor of CT: overload protection, input power loss the phase protection, motor block protection, controller over temperature protection, low load protection, exceed sensitive reaction, and no thermal effect, not affected by ambient temperature.
8. The machine has 3 sets output connection points: The output point when starting (Running), after running the output contacts (by Pass), and output point for system abnormal (NO, COM NC).
9. This machine has soft stop function for pump motor to create best water hammer removing result